Specifications
Brand
LappCross Sectional Area
1.5 mm²
Number of Cores
4
Sheath Colour
Black
Length
50m
Cable Type
Flat
Outer Diameter
17.5mm
Sheath Material
Rubber
Voltage Rating
500 V
Series
ÖLFLEX
Conductor Material
Copper
Maximum Operating Temperature
+90°C
American Wire Gauge
15 AWG
Insulation material
Rubber
Fire Behaviour
Flame Retardant
Minimum Operating Temperature
-25°C
Standards Met
CE
Country of Origin
Germany
Product details
Ölflex Flat Conveyor, Crane and Hoist Cable
NEOFLEX® (CRANE F) Flat Form Cable is a polychloroprene flat cable for application in rooms as well as in the open as a power and control cable.
Plain copper stranded wire conductor
Core insulation: rubber compound 3GI3 in accordance with VDE 0207 part 20
Colour code in accordance with VDE 0293
Outer sheath: polychloroprene compound 5GM3 in accordance with VDE 0207 part 21 (black)
Working voltage (at 20°C): 300 / 500V; test voltage: 3000Vac
Minimum bending radius: 10x cable diameter
Cold impact resistance in accordance with VDE 0472 part 611, in case of -50°C
Flame-retardant in accordance with VDE 0482 part 265-2-1 (IEC 60332-1)
EC directive: conforms to ECD 73/23/EEC (low voltage directive)
Stock information temporarily unavailable.
Please check again later.
€ 570.28
1 Reel of 50 Metres (Exc. VAT)
€ 672.93
1 Reel of 50 Metres (inc. VAT)
1
€ 570.28
1 Reel of 50 Metres (Exc. VAT)
€ 672.93
1 Reel of 50 Metres (inc. VAT)
1
Technical Document
Specifications
Brand
LappCross Sectional Area
1.5 mm²
Number of Cores
4
Sheath Colour
Black
Length
50m
Cable Type
Flat
Outer Diameter
17.5mm
Sheath Material
Rubber
Voltage Rating
500 V
Series
ÖLFLEX
Conductor Material
Copper
Maximum Operating Temperature
+90°C
American Wire Gauge
15 AWG
Insulation material
Rubber
Fire Behaviour
Flame Retardant
Minimum Operating Temperature
-25°C
Standards Met
CE
Country of Origin
Germany
Product details
Ölflex Flat Conveyor, Crane and Hoist Cable
NEOFLEX® (CRANE F) Flat Form Cable is a polychloroprene flat cable for application in rooms as well as in the open as a power and control cable.
Plain copper stranded wire conductor
Core insulation: rubber compound 3GI3 in accordance with VDE 0207 part 20
Colour code in accordance with VDE 0293
Outer sheath: polychloroprene compound 5GM3 in accordance with VDE 0207 part 21 (black)
Working voltage (at 20°C): 300 / 500V; test voltage: 3000Vac
Minimum bending radius: 10x cable diameter
Cold impact resistance in accordance with VDE 0472 part 611, in case of -50°C
Flame-retardant in accordance with VDE 0482 part 265-2-1 (IEC 60332-1)
EC directive: conforms to ECD 73/23/EEC (low voltage directive)