Technical Document
Specifications
Brand
FlukeAbsolute Maximum AC Current Measurement
1.4kA ac
Absolute Maximum DC Current Measurement
2000A dc
Absolute Maximum AC Voltage Measurement
825V ac
Absolute Maximum DC Voltage Measurement
825V dc
Model Number
345
Calibrated
RSCAL
AC Current Measurement Resolution
10mA ac
DC Current Measurement Resolution
10mA dc
Best DC Current Accuracy
±1.5% + 5 Digits
Clamp Meter Type
Power Clamp Meter
Best AC Current Accuracy
±1.5% +5 digits
Best AC Voltage Accuracy
±1.5% + 5 Digits
True RMS
Yes
Functions Measured
AC Current, AC Voltage, DC Current, DC Voltage, Frequency, Harmonics, Kilowatt Hour, Power, Power Factor, VAR, Voltage
Best DC Voltage Accuracy
±1.5% + 5 Digits
Width
98mm
Dimensions
300 x 98 x 52mm
Minimum Operating Temperature
0°C
Height
52mm
AC Voltage Measurement Resolution
1mV ac
Battery Life
10 (Backlight On) h, 12 (Backlight Off) h
Maximum Conductor Size
58mm
Maximum Operating Temperature
+50°C
Safety Category Level
CAT IV
Safety Category Voltage
600V
Battery Type
AA
Safety Category
CAT IV 600 V
Display Type
LCD
Power Source
Battery
Length
300mm
DC Voltage Measurement Resolution
1mV dc
Weight
820g
Country of Origin
Malaysia
Product details
Fluke 345 Power Quality Clamp Meter
The Fluke 345 measures a wide range of electrical parameters for troubleshooting power disturbances in single- and three phase electrical loads. With a bright colour display to see waveforms and trends, a low-pass filter to remove high frequency noise, and a high EMC immunity design, the Fluke 345 is ideal for measurements on switching loads such as variable speed drives, electronic lighting and UPS systems.
Clamp-on measurement of ac current up to 1400A rms and dc current up to 2000A without breaking the circuit
Low pass filter ensures the clamp meter is accurate in noisy environments even with distorted waveforms present on electronic loads
Identify intermittent faults by logging any power quality parameter for minutes, or over a month, including harmonics
Direct measurement of dc ripple (%) for battery and dc systems
Analyse and log harmonics digitally or graphically
Inrush current measurement to capture and analyse nuisance tripping, from 3 to 300 seconds
Large backlit colour display of waveforms (scope function) and trends
Balanced 3-phase power measurement capability
Power Log software supplied to view graphs and generate reports on a PC
USB interface
Harmonic analysis: Analyse, display and log harmonics up to the 30th harmonic (40th harmonic for 15Hz to 22Hz)
Verify batteries: Direct measurement of dc ripple (%) for battery and dc systems
EN61010 safety rating: 600V CAT IV / 1000V CAT III rated for use at the service entrance
Supplied with
Test Leads, Power Log software on CD-ROM, USB lead, batteries(fitted), mains adaptor, carry case & instructions.
Stock information temporarily unavailable.
Please check again later.
P.O.A.
Calibration type
RS Calibration
1
P.O.A.
Calibration type
RS Calibration
1
Technical Document
Specifications
Brand
FlukeAbsolute Maximum AC Current Measurement
1.4kA ac
Absolute Maximum DC Current Measurement
2000A dc
Absolute Maximum AC Voltage Measurement
825V ac
Absolute Maximum DC Voltage Measurement
825V dc
Model Number
345
Calibrated
RSCAL
AC Current Measurement Resolution
10mA ac
DC Current Measurement Resolution
10mA dc
Best DC Current Accuracy
±1.5% + 5 Digits
Clamp Meter Type
Power Clamp Meter
Best AC Current Accuracy
±1.5% +5 digits
Best AC Voltage Accuracy
±1.5% + 5 Digits
True RMS
Yes
Functions Measured
AC Current, AC Voltage, DC Current, DC Voltage, Frequency, Harmonics, Kilowatt Hour, Power, Power Factor, VAR, Voltage
Best DC Voltage Accuracy
±1.5% + 5 Digits
Width
98mm
Dimensions
300 x 98 x 52mm
Minimum Operating Temperature
0°C
Height
52mm
AC Voltage Measurement Resolution
1mV ac
Battery Life
10 (Backlight On) h, 12 (Backlight Off) h
Maximum Conductor Size
58mm
Maximum Operating Temperature
+50°C
Safety Category Level
CAT IV
Safety Category Voltage
600V
Battery Type
AA
Safety Category
CAT IV 600 V
Display Type
LCD
Power Source
Battery
Length
300mm
DC Voltage Measurement Resolution
1mV dc
Weight
820g
Country of Origin
Malaysia
Product details
Fluke 345 Power Quality Clamp Meter
The Fluke 345 measures a wide range of electrical parameters for troubleshooting power disturbances in single- and three phase electrical loads. With a bright colour display to see waveforms and trends, a low-pass filter to remove high frequency noise, and a high EMC immunity design, the Fluke 345 is ideal for measurements on switching loads such as variable speed drives, electronic lighting and UPS systems.
Clamp-on measurement of ac current up to 1400A rms and dc current up to 2000A without breaking the circuit
Low pass filter ensures the clamp meter is accurate in noisy environments even with distorted waveforms present on electronic loads
Identify intermittent faults by logging any power quality parameter for minutes, or over a month, including harmonics
Direct measurement of dc ripple (%) for battery and dc systems
Analyse and log harmonics digitally or graphically
Inrush current measurement to capture and analyse nuisance tripping, from 3 to 300 seconds
Large backlit colour display of waveforms (scope function) and trends
Balanced 3-phase power measurement capability
Power Log software supplied to view graphs and generate reports on a PC
USB interface
Harmonic analysis: Analyse, display and log harmonics up to the 30th harmonic (40th harmonic for 15Hz to 22Hz)
Verify batteries: Direct measurement of dc ripple (%) for battery and dc systems
EN61010 safety rating: 600V CAT IV / 1000V CAT III rated for use at the service entrance
Supplied with
Test Leads, Power Log software on CD-ROM, USB lead, batteries(fitted), mains adaptor, carry case & instructions.