Fluke I430-FLEXI-TF-II, Accessory Type Rogowski Coil

RS Stock No.: 818-7357Brand: FlukeManufacturers Part No.: I430-FLEXI-TF-II
brand-logo

Technical Document

Specifications

Brand

Fluke

Accessory Type

Rogowski Coil

For Use With

Fluke 433/434/435/434-II/435-II/437-II

Country of Origin

Bulgaria

Product details

i430-Flexi-TF-II 6000A Flexible AC Current Probe

The i430-Flexi-TF-II flexible AC current probe is optimized for current measurement on thick and hard to reach conductors. The i430-Flexi-TF-II is a flexible AC current probe for use with the Fluke 430 series Power Quality Analyzers including Series II.

Measuring range: 0.5 to 6000 A ac
Bandwidth (-3 dB): 10 Hz to 10 kHz
Output signal: 86.6 mV at 1000A/50Hz (on 1 MΩ), 85.0 mV at 1000A/50Hz (on 50 kΩ)
Maximum non-destructive current: 100 kA (50/60 Hz)
Transducer length: 610 mm (24 in)
Transducer diameter: 7.5 mm (0.3 in)
Minimum bending radius: 38 mm (1.5 in)
Cable length from transducer to BNC: 2.5 m (98.4 in)
Complies with: IEC 61010-1: Pollution degree 2, IEC 61010-2-032: 1000V CAT III/ 600V CAT IV, IEC 61010-031

Supplied with

Instruction Sheet

Stock information temporarily unavailable.

Please check again later.

Stock information temporarily unavailable.

€ 1,455.82

Each (Exc. Vat)

€ 1,717.87

Each (Including VAT)

Fluke I430-FLEXI-TF-II, Accessory Type Rogowski Coil

€ 1,455.82

Each (Exc. Vat)

€ 1,717.87

Each (Including VAT)

Fluke I430-FLEXI-TF-II, Accessory Type Rogowski Coil
Stock information temporarily unavailable.

Technical Document

Specifications

Brand

Fluke

Accessory Type

Rogowski Coil

For Use With

Fluke 433/434/435/434-II/435-II/437-II

Country of Origin

Bulgaria

Product details

i430-Flexi-TF-II 6000A Flexible AC Current Probe

The i430-Flexi-TF-II flexible AC current probe is optimized for current measurement on thick and hard to reach conductors. The i430-Flexi-TF-II is a flexible AC current probe for use with the Fluke 430 series Power Quality Analyzers including Series II.

Measuring range: 0.5 to 6000 A ac
Bandwidth (-3 dB): 10 Hz to 10 kHz
Output signal: 86.6 mV at 1000A/50Hz (on 1 MΩ), 85.0 mV at 1000A/50Hz (on 50 kΩ)
Maximum non-destructive current: 100 kA (50/60 Hz)
Transducer length: 610 mm (24 in)
Transducer diameter: 7.5 mm (0.3 in)
Minimum bending radius: 38 mm (1.5 in)
Cable length from transducer to BNC: 2.5 m (98.4 in)
Complies with: IEC 61010-1: Pollution degree 2, IEC 61010-2-032: 1000V CAT III/ 600V CAT IV, IEC 61010-031

Supplied with

Instruction Sheet