Honeywell CSL Series Current Transformer, Maximum of 550 A Output, 6 → 12 V dc

RS Stock No.: 169-7654Brand: HoneywellManufacturers Part No.: CSLA2EL
brand-logo
View all in Current Transformers

Technical Document

Specifications

Supply Voltage

6 → 12 V dc

Output Current

Maximum of 550 A

Overall Height

57.4mm

Overall Width

44.4mm

Overall Depth

15.7mm

Minimum Temperature

-25°C

Maximum Temperature

+85°C

Mounting Type

PCB Mount

Series

CSL

Country of Origin

New Zealand

Product details

Honeywell CSLA Series LOHET II Current Sensors

Linear current sensors from Honeywell incorporating LOHET II Hall effect transducers. These devices have increased temperature stability and 10 times less temperature drift than the LOHET I types and produce a ratiometric output voltage that varies from 19% to 81% of the supply voltage as the magnetic field varies within the rated flux range. They have push-pull outputs which are capable of sourcing and sinking current.

• AC or DC current sensing with linear output
• Fast response time
• Output voltage isolated from input
• Maximum current limited only by conductor size
• Simple through-hole design
• Operating temperature range -25 to 85°C

Stock information temporarily unavailable.

Please check again later.

Stock information temporarily unavailable.

P.O.A.

Honeywell CSL Series Current Transformer, Maximum of 550 A Output, 6 → 12 V dc

P.O.A.

Honeywell CSL Series Current Transformer, Maximum of 550 A Output, 6 → 12 V dc
Stock information temporarily unavailable.

Technical Document

Specifications

Supply Voltage

6 → 12 V dc

Output Current

Maximum of 550 A

Overall Height

57.4mm

Overall Width

44.4mm

Overall Depth

15.7mm

Minimum Temperature

-25°C

Maximum Temperature

+85°C

Mounting Type

PCB Mount

Series

CSL

Country of Origin

New Zealand

Product details

Honeywell CSLA Series LOHET II Current Sensors

Linear current sensors from Honeywell incorporating LOHET II Hall effect transducers. These devices have increased temperature stability and 10 times less temperature drift than the LOHET I types and produce a ratiometric output voltage that varies from 19% to 81% of the supply voltage as the magnetic field varies within the rated flux range. They have push-pull outputs which are capable of sourcing and sinking current.

• AC or DC current sensing with linear output
• Fast response time
• Output voltage isolated from input
• Maximum current limited only by conductor size
• Simple through-hole design
• Operating temperature range -25 to 85°C