Technical Document
Specifications
Brand
Red LionOutput Type
Alarm, Linear, Logic, Relay, SSR
Supply Voltage
18 → 36 V dc, 85 → 250 V ac, 24 V ac
Size
49.5 x 49.5mm
Number of Inputs
1
Number of Outputs
2
Minimum Operating Temperature
0°C
Maximum Operating Temperature
+50°C
Temperature Range
+149 → +1820 (Type B Thermocouple) °C, 0 → +1768 (Type R Thermocouple) °C, 0 → +1768 (Type S Thermocouple) °C, -200 → +1250 (Type K Thermocouple) °C, -200 → +1300 (Type N Thermocouple) °C, -200 → +400 (Type T Thermocouple) °C, -200 → +600 (RTD 385)
Communication Module Available
Yes
Display Type
4 Digit
IP Rating
IP20, IP65
Mounting Type
Panel Mount
Input Type
RTD (2 Wire), RTD (3 Wire), RTD (385), RTD (392), Type B Thermocouple, Type E Thermocouple, Type K Thermocouple, Type N Thermocouple, Type R Thermocouple, Type S Thermocouple, Type T Thermocouple
Series
T48
Additional Functionality
PID Function Only
Display Colour
Green (Bottom), Red (Top)
Termination Type
Screw
Panel Depth
105.9mm
Country of Origin
United States
Product details
T48 PID Temperature Controller
The T48 PID controller accepts signals from various temperature sensors and precisely displays the process temperature. It also provides an accurate output control signal (time proportional or linear DC) to maintain the process at the desired temperature.
The controllers comprehensive yet simple programming allows it to meet a wide variety of application requirements.
2 line by 4-digit (10.2 mm top line, 7.6 mm, bottom line) LED display
PID control with reduced overshoot
On-demand auto-tuning of PID control settings
Dual LED displays for simultaneous indication of temperature and setpoint
Status indicators for outputs and control modes
Accepts 10 types of sensor inputs (thermocouple of RTD)
Optional heater current monitor and heater break alarm
Optional dual alarm outputs
Optional 2 linear DC outputs (0-10V, 0/4-20 mA)
Manual/automatic control modes
Setpoint ramping for process startup
Programmable user input (digital) for added flexibility
Heating and optional cooling outputs
Red Lion Temperature Controllers
Stock information temporarily unavailable.
Please check again later.
P.O.A.
1
P.O.A.
1
Technical Document
Specifications
Brand
Red LionOutput Type
Alarm, Linear, Logic, Relay, SSR
Supply Voltage
18 → 36 V dc, 85 → 250 V ac, 24 V ac
Size
49.5 x 49.5mm
Number of Inputs
1
Number of Outputs
2
Minimum Operating Temperature
0°C
Maximum Operating Temperature
+50°C
Temperature Range
+149 → +1820 (Type B Thermocouple) °C, 0 → +1768 (Type R Thermocouple) °C, 0 → +1768 (Type S Thermocouple) °C, -200 → +1250 (Type K Thermocouple) °C, -200 → +1300 (Type N Thermocouple) °C, -200 → +400 (Type T Thermocouple) °C, -200 → +600 (RTD 385)
Communication Module Available
Yes
Display Type
4 Digit
IP Rating
IP20, IP65
Mounting Type
Panel Mount
Input Type
RTD (2 Wire), RTD (3 Wire), RTD (385), RTD (392), Type B Thermocouple, Type E Thermocouple, Type K Thermocouple, Type N Thermocouple, Type R Thermocouple, Type S Thermocouple, Type T Thermocouple
Series
T48
Additional Functionality
PID Function Only
Display Colour
Green (Bottom), Red (Top)
Termination Type
Screw
Panel Depth
105.9mm
Country of Origin
United States
Product details
T48 PID Temperature Controller
The T48 PID controller accepts signals from various temperature sensors and precisely displays the process temperature. It also provides an accurate output control signal (time proportional or linear DC) to maintain the process at the desired temperature.
The controllers comprehensive yet simple programming allows it to meet a wide variety of application requirements.
2 line by 4-digit (10.2 mm top line, 7.6 mm, bottom line) LED display
PID control with reduced overshoot
On-demand auto-tuning of PID control settings
Dual LED displays for simultaneous indication of temperature and setpoint
Status indicators for outputs and control modes
Accepts 10 types of sensor inputs (thermocouple of RTD)
Optional heater current monitor and heater break alarm
Optional dual alarm outputs
Optional 2 linear DC outputs (0-10V, 0/4-20 mA)
Manual/automatic control modes
Setpoint ramping for process startup
Programmable user input (digital) for added flexibility
Heating and optional cooling outputs