STUDENT PROJECT FUND

Propel Your Engineering Dreams! Join the Student Project Fund – Now Open in Malta! Innovate with RS Products and Shape a Sustainable Future. Apply Today!

Click here to Apply

Chauvin Arnoux F402 Clamp Meter, Max Current 1000A ac CAT III 1500V

RS Stock No.: 766-0602Brand: Chauvin ArnouxManufacturers Part No.: P01120942
brand-logo
View all in Clamp Meters

Technical Document

Specifications

Absolute Maximum AC Current Measurement

1000A ac

Absolute Maximum AC Voltage Measurement

1200V ac

Absolute Maximum DC Voltage Measurement

1700V dc

Absolute Maximum Resistance Measurement

99.99kΩ

Model Number

F402

AC Current Measurement Resolution

10mA

Clamp Meter Type

AC Current Clamp Meter

Best AC Current Accuracy

±(1% rdg + 3dgts)

Best AC Voltage Accuracy

±(1% rdg + 3dgts)

Best DC Voltage Accuracy

±(1% rdg + 3dgts)

Functions Measured

AC Current, AC Voltage, Continuity, DC Voltage, Diode, Frequency, In-Rush Current, Resistance, Temperature

True RMS

Yes

Jaw Capacity Busbars

48mm

Absolute Maximum Temperature Measurement

+1000°C

Safety Category

CAT III 1500 V, CAT IV 1000V

Best Resistance Measurement Accuracy

±1 % + 5 digits

Display Type

Backlit LCD

Maximum Operating Temperature

+55°C

Power Source

Battery

Non-Contact Voltage Detector

No

Width

92mm

Length

272mm

Resistance Measurement Resolution

100mΩ

Dimensions

92 x 272 x 41mm

DC Voltage Measurement Resolution

10mV

Best Temperature Measurement Accuracy

±1% +3°C

Minimum Operating Temperature

-20°C

Height

41mm

AC Voltage Measurement Resolution

10mV

AC Current Measurement Range

0.25 to 1000 A AC

AC Voltage Measurement Range

0.15 to 1200 V AC

Maximum Conductor Size

48mm

Battery Life

>350 h

Safety Category Level

CAT III, CAT IV

Temperature Measurement Resolution

0.1°C

Safety Category Voltage

CAT III 1500 V, CAT IV 1000V

Battery Type

LR6

Weight

600g

Country of Origin

China

Product details

F401 TRMS Clamp Multimeter

The F401 clampmeter is designed for medium-power low-voltage applications in sectors such as LV electricity production and distribution, industry, railways
This clamp multimeter is also suitable for lift/elevator technicians and other lifting and transport specialists
The applications for the clamp multimeter are maintenance, testing, monitoring, diagnostics and connection
Equipped with a fast 12-bit TRMS digital acquisition system
Automatic AC/DC detection
AC and DC voltage up to 1000 V
Resistance and audible continuity
Min and Max analysis
TrueInrush current measurement
Temperature
IP54 protection

Stock information temporarily unavailable.

Please check again later.

Stock information temporarily unavailable.

€ 573.77

Each (Exc. VAT)

€ 677.05

Each (inc. VAT)

Chauvin Arnoux F402 Clamp Meter, Max Current 1000A ac CAT III 1500V

Calibration type

€ 573.77

Each (Exc. VAT)

€ 677.05

Each (inc. VAT)

Chauvin Arnoux F402 Clamp Meter, Max Current 1000A ac CAT III 1500V
Stock information temporarily unavailable.

Calibration type

Technical Document

Specifications

Absolute Maximum AC Current Measurement

1000A ac

Absolute Maximum AC Voltage Measurement

1200V ac

Absolute Maximum DC Voltage Measurement

1700V dc

Absolute Maximum Resistance Measurement

99.99kΩ

Model Number

F402

AC Current Measurement Resolution

10mA

Clamp Meter Type

AC Current Clamp Meter

Best AC Current Accuracy

±(1% rdg + 3dgts)

Best AC Voltage Accuracy

±(1% rdg + 3dgts)

Best DC Voltage Accuracy

±(1% rdg + 3dgts)

Functions Measured

AC Current, AC Voltage, Continuity, DC Voltage, Diode, Frequency, In-Rush Current, Resistance, Temperature

True RMS

Yes

Jaw Capacity Busbars

48mm

Absolute Maximum Temperature Measurement

+1000°C

Safety Category

CAT III 1500 V, CAT IV 1000V

Best Resistance Measurement Accuracy

±1 % + 5 digits

Display Type

Backlit LCD

Maximum Operating Temperature

+55°C

Power Source

Battery

Non-Contact Voltage Detector

No

Width

92mm

Length

272mm

Resistance Measurement Resolution

100mΩ

Dimensions

92 x 272 x 41mm

DC Voltage Measurement Resolution

10mV

Best Temperature Measurement Accuracy

±1% +3°C

Minimum Operating Temperature

-20°C

Height

41mm

AC Voltage Measurement Resolution

10mV

AC Current Measurement Range

0.25 to 1000 A AC

AC Voltage Measurement Range

0.15 to 1200 V AC

Maximum Conductor Size

48mm

Battery Life

>350 h

Safety Category Level

CAT III, CAT IV

Temperature Measurement Resolution

0.1°C

Safety Category Voltage

CAT III 1500 V, CAT IV 1000V

Battery Type

LR6

Weight

600g

Country of Origin

China

Product details

F401 TRMS Clamp Multimeter

The F401 clampmeter is designed for medium-power low-voltage applications in sectors such as LV electricity production and distribution, industry, railways
This clamp multimeter is also suitable for lift/elevator technicians and other lifting and transport specialists
The applications for the clamp multimeter are maintenance, testing, monitoring, diagnostics and connection
Equipped with a fast 12-bit TRMS digital acquisition system
Automatic AC/DC detection
AC and DC voltage up to 1000 V
Resistance and audible continuity
Min and Max analysis
TrueInrush current measurement
Temperature
IP54 protection