Technical Document
Specifications
Brand
FlukeMaximum Pressure Measurement
20bar
Minimum Pressure Measurement
-830mbar
Resolution
0.0001 bar
Pressure Port Type
Vacuum
Model Number p
718 EX
Intrinsically Safe
Yes
Current Loop Measurement
Yes
Maximum Operating Temperature
+55°C
Minimum Operating Temperature
-10°C
Weight
992g
Dimensions
216 x 94 x 66mm
Height
66mm
Length
216mm
Hazardous Area Certification
ATEX
Width
94mm
Country of Origin
China
Product details
Fluke 718Ex 300G Pressure Calibrator
Pressure calibrator designed for use in potentially explosive areas.
Pressure sensor input of 20 bars full scale with 0.05% accuracy.
Built-in pressure / vacuum hand pump, with vernier and bleed valve.
Measures pressure up to 200 bar (using one of the eight intrinsically safe Fluke 700PEx pressure modules).
Current measurement with 0.02% accuracy and 0.001 mA resolution.
Supported units of pressure: psi, inH2O (4°C), inH2O (20°C), kPa, cmH2O (4°C), cmH2O (20°C), bar, mbar, kg/cm2, mmHg, inHg.
Pressure switch test function.
Zero, Min/Max and Hold display functions.
Compatible with non-corrosive gases.
Supplied with
Protective red holster, TL75 test leads, set of test clips (red and black).
Standards
ATEX II 1G EEx ia IIC T4 compliant, CSA I.S. Class I, Div. 1 Groups A-D, T4, EN 61326 2002-2, Class C
Stock information temporarily unavailable.
Please check again later.
€ 9,047.99
Each (Exc. VAT)
€ 10,676.63
Each (inc. VAT)
Calibration type
No Calibration
1
€ 9,047.99
Each (Exc. VAT)
€ 10,676.63
Each (inc. VAT)
Calibration type
No Calibration
1
Technical Document
Specifications
Brand
FlukeMaximum Pressure Measurement
20bar
Minimum Pressure Measurement
-830mbar
Resolution
0.0001 bar
Pressure Port Type
Vacuum
Model Number p
718 EX
Intrinsically Safe
Yes
Current Loop Measurement
Yes
Maximum Operating Temperature
+55°C
Minimum Operating Temperature
-10°C
Weight
992g
Dimensions
216 x 94 x 66mm
Height
66mm
Length
216mm
Hazardous Area Certification
ATEX
Width
94mm
Country of Origin
China
Product details
Fluke 718Ex 300G Pressure Calibrator
Pressure calibrator designed for use in potentially explosive areas.
Pressure sensor input of 20 bars full scale with 0.05% accuracy.
Built-in pressure / vacuum hand pump, with vernier and bleed valve.
Measures pressure up to 200 bar (using one of the eight intrinsically safe Fluke 700PEx pressure modules).
Current measurement with 0.02% accuracy and 0.001 mA resolution.
Supported units of pressure: psi, inH2O (4°C), inH2O (20°C), kPa, cmH2O (4°C), cmH2O (20°C), bar, mbar, kg/cm2, mmHg, inHg.
Pressure switch test function.
Zero, Min/Max and Hold display functions.
Compatible with non-corrosive gases.
Supplied with
Protective red holster, TL75 test leads, set of test clips (red and black).
Standards
ATEX II 1G EEx ia IIC T4 compliant, CSA I.S. Class I, Div. 1 Groups A-D, T4, EN 61326 2002-2, Class C