STUDENT PROJECT FUND

Propel Your Engineering Dreams! Join the Student Project Fund – Now Open in Malta! Innovate with RS Products and Shape a Sustainable Future. Apply Today!

Click here to Apply

Teledyne LeCroy HVD 3000 Series Oscilloscope Probe, Differential Type, 120MHz, 500x, 50x

RS Stock No.: 901-0999Brand: LeCroyManufacturers Part No.: HVD3106-NOACC
brand-logo
View all in Oscilloscope Probes

Technical Document

Specifications

Brand

LeCroy

Probe Type

Differential

Attenuation

500x, 50x

Bandwidth

120MHz

Maximum Common Mode Input Voltage

1000 Vrms, ±1500 (dc + pk ac) V

Number of Probes

2

Safety Category Level

CAT III

Series

HVD 3000

Safety Category

CAT III 1000 Vrms

Rise Time

2.9ns

Country of Origin

United States

Product details

Teledyne LeCroy HVD3000A Series Probes

Teledyne LeCroy’s HVD3106A series of high voltage differential probes cover the fullest range of applications, from 120/240 V switch-mode power supplies through 600 V class and 1.5 kV electrical apparatus. The 1% gain accuracy coupled with exceptional common-mode rejection ratio provides an accurate and versatile probe suitable for use with a wide range of oscilloscopes

Features and Benefits

  • Exceptional common-mode rejection ratio (CMRR) across a broad frequency range

  • 1% gain accuracy

  • High offset capability at both high and low attenuation

  • AC and DC coupling

  • ProBus active probe interface with automatic scaling

  • AutoZero with auto disconnect switch

  • Wide oscilloscope compatibility

Applications

  • Applications

  • Automotive

  • Power Applications

  • Motor Drive Development

  • Product Design Applications

  • 174-8868 - 1kV, 120 MHz High Voltage Differential Probe without tip Accessories and with Auto Zero Disconnect

  • 174-8869 1kV, 120 MHz High Voltage Differential Probe with Auto Zero Disconnect

  • 174-8870 - 1kV, 80 MHz High Voltage Differential Probe with 6m cable and Auto Zero Disconnect

Supplied with

174-8869 and 174-8870 are supplied with = a Pair of Red & Black 1000V Safety Alligator Clips, Plunger Pincer Clips, Plunger Hook Clips, Plunger Alligator Clips and Spade Terminals

Stock information temporarily unavailable.

Please check again later.

Stock information temporarily unavailable.

P.O.A.

Teledyne LeCroy HVD 3000 Series Oscilloscope Probe, Differential Type, 120MHz, 500x, 50x

P.O.A.

Teledyne LeCroy HVD 3000 Series Oscilloscope Probe, Differential Type, 120MHz, 500x, 50x
Stock information temporarily unavailable.

Technical Document

Specifications

Brand

LeCroy

Probe Type

Differential

Attenuation

500x, 50x

Bandwidth

120MHz

Maximum Common Mode Input Voltage

1000 Vrms, ±1500 (dc + pk ac) V

Number of Probes

2

Safety Category Level

CAT III

Series

HVD 3000

Safety Category

CAT III 1000 Vrms

Rise Time

2.9ns

Country of Origin

United States

Product details

Teledyne LeCroy HVD3000A Series Probes

Teledyne LeCroy’s HVD3106A series of high voltage differential probes cover the fullest range of applications, from 120/240 V switch-mode power supplies through 600 V class and 1.5 kV electrical apparatus. The 1% gain accuracy coupled with exceptional common-mode rejection ratio provides an accurate and versatile probe suitable for use with a wide range of oscilloscopes

Features and Benefits

  • Exceptional common-mode rejection ratio (CMRR) across a broad frequency range

  • 1% gain accuracy

  • High offset capability at both high and low attenuation

  • AC and DC coupling

  • ProBus active probe interface with automatic scaling

  • AutoZero with auto disconnect switch

  • Wide oscilloscope compatibility

Applications

  • Applications

  • Automotive

  • Power Applications

  • Motor Drive Development

  • Product Design Applications

  • 174-8868 - 1kV, 120 MHz High Voltage Differential Probe without tip Accessories and with Auto Zero Disconnect

  • 174-8869 1kV, 120 MHz High Voltage Differential Probe with Auto Zero Disconnect

  • 174-8870 - 1kV, 80 MHz High Voltage Differential Probe with 6m cable and Auto Zero Disconnect

Supplied with

174-8869 and 174-8870 are supplied with = a Pair of Red & Black 1000V Safety Alligator Clips, Plunger Pincer Clips, Plunger Hook Clips, Plunger Alligator Clips and Spade Terminals