RS PRO, MAXX Surge Suppressor Unit 253V Maximum Voltage Rating 6.5 kA Maximum Surge Current EMC Filter

Technical Document
Specifications
Brand
RS ProProduct Type
Surge Suppressor Unit
Suppressor Type
EMC Filter
Maximum Voltage
253V
Mount Type
DIN Rail
Maximum Surge Current
6.5kA
Series
MAXX
Minimum Operating Temperature
-25°C
Maximum Operating Temperature
85°C
Standards/Approvals
ANSI/ESD S20.20:2014
Hazardous Area Certification
No
Product details
Surge & Noise Suppressor, MAxx / D Series
Combined surge and RFI filter units
Includes EMI / RFI filter
Warning
Will not pass a 500V insulation test.
Surge Protection Devices, SPDs (DIN-rail)
Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.
Stock information temporarily unavailable.
€ 464.05
€ 464.05 Each (Exc. VAT)
€ 547.58
€ 547.58 Each (inc. VAT)
1
€ 464.05
€ 464.05 Each (Exc. VAT)
€ 547.58
€ 547.58 Each (inc. VAT)
Stock information temporarily unavailable.
1
| Quantity | Unit price |
|---|---|
| 1 - 1 | € 464.05 |
| 2 - 4 | € 452.32 |
| 5+ | € 435.27 |
Technical Document
Specifications
Brand
RS ProProduct Type
Surge Suppressor Unit
Suppressor Type
EMC Filter
Maximum Voltage
253V
Mount Type
DIN Rail
Maximum Surge Current
6.5kA
Series
MAXX
Minimum Operating Temperature
-25°C
Maximum Operating Temperature
85°C
Standards/Approvals
ANSI/ESD S20.20:2014
Hazardous Area Certification
No
Product details
Surge & Noise Suppressor, MAxx / D Series
Combined surge and RFI filter units
Includes EMI / RFI filter
Warning
Will not pass a 500V insulation test.
Surge Protection Devices, SPDs (DIN-rail)
Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.